Notice: A non well formed numeric value encountered in /home/powerexi/public_html/wp-content/plugins/script-insert/inc/php/versioning.php on line 41
Emergency Oxygen Supply Connection | POWEREX Notice: Function WP_Scripts::localize was called incorrectly. The $l10n parameter must be an array. To pass arbitrary data to scripts, use the wp_add_inline_script() function instead. Please see Debugging in WordPress for more information. (This message was added in version 5.7.0.) in /home/powerexi/public_html/wp-includes/functions.php on line 5833
Notice: Function WP_Scripts::localize was called incorrectly. The $l10n parameter must be an array. To pass arbitrary data to scripts, use the wp_add_inline_script() function instead. Please see Debugging in WordPress for more information. (This message was added in version 5.7.0.) in /home/powerexi/public_html/wp-includes/functions.php on line 5833
Notice: Function WP_Scripts::localize was called incorrectly. The $l10n parameter must be an array. To pass arbitrary data to scripts, use the wp_add_inline_script() function instead. Please see Debugging in WordPress for more information. (This message was added in version 5.7.0.) in /home/powerexi/public_html/wp-includes/functions.php on line 5833
Notice: Function WP_Scripts::localize was called incorrectly. The $l10n parameter must be an array. To pass arbitrary data to scripts, use the wp_add_inline_script() function instead. Please see Debugging in WordPress for more information. (This message was added in version 5.7.0.) in /home/powerexi/public_html/wp-includes/functions.php on line 5833
The Powerex Emergency Oxygen Supply Connection Box provides an inlet for connecting a temporary auxiliary source of oxygen to the oxygen pipeline system for emergency or maintenance situations as recommended by NFPA 99. The EOSC Boxes are housed in a rugged, 16-gauge weather-tight enclosure with keyed lock to prevent tampering or unauthorized access.
The Powerex Emergency Oxygen Supply Connection Box provides an inlet for connecting a temporary auxiliary source of oxygen to the oxygen pipeline system for emergency or maintenance situations as recommended by NFPA 99.
Built by Powerex in Harrison, OH
5 year warranty on parts, 2 year warranty on labor
Designed in accordance with NFPA 99
Rugged 16 gauge weather-tight enclosure with keyed lock to prevent tampering or unauthorized access
The inlet will consist of 1” ball valve with 1” NPT connection or a 2” ball valve with 2” NPT connection and a pressure gauge
75 PSI Safety relief valve with 1/2” NPT connections included with each EOSC
Entire assembly is cleaned for oxygen service and capped