Notice: A non well formed numeric value encountered in /home/powerexi/public_html/wp-content/plugins/script-insert/inc/php/versioning.php on line 41
Medical Vacuum Filter | POWEREX Notice: Function WP_Scripts::localize was called incorrectly. The $l10n parameter must be an array. To pass arbitrary data to scripts, use the wp_add_inline_script() function instead. Please see Debugging in WordPress for more information. (This message was added in version 5.7.0.) in /home/powerexi/public_html/wp-includes/functions.php on line 5833
Notice: Function WP_Scripts::localize was called incorrectly. The $l10n parameter must be an array. To pass arbitrary data to scripts, use the wp_add_inline_script() function instead. Please see Debugging in WordPress for more information. (This message was added in version 5.7.0.) in /home/powerexi/public_html/wp-includes/functions.php on line 5833
Notice: Function WP_Scripts::localize was called incorrectly. The $l10n parameter must be an array. To pass arbitrary data to scripts, use the wp_add_inline_script() function instead. Please see Debugging in WordPress for more information. (This message was added in version 5.7.0.) in /home/powerexi/public_html/wp-includes/functions.php on line 5833
Notice: Function WP_Scripts::localize was called incorrectly. The $l10n parameter must be an array. To pass arbitrary data to scripts, use the wp_add_inline_script() function instead. Please see Debugging in WordPress for more information. (This message was added in version 5.7.0.) in /home/powerexi/public_html/wp-includes/functions.php on line 5833
Powerex Medical Vacuum Filter Assemblies are designed to protect the service professionals who perform maintenance on the vacuum units. The filters remove solid, liquid, and bacterial contamination as small as 0.3 micron with 99.995% efficiency through HEPA-grade filters.
These units must be used in conjunction with a medical vacuum system to be compliant with the 2018 revision of NFPA 99 (5.1.3.7.4), which requires the addition of inlet bacteriologic filtration at the medical vacuum source. The filter units include:
Multiple filters mounted to a metal frame
Single point connections for inlet and outlet pipes
Isolation valves on source side and patient side for each filter
Clear Borosil glass flask to easily detect liquid accumulation
* HTM 02-01 requires full 100% redundancy. MVF15D, MVF20D, and MVF30D meet this standard. MVF40Q meets the standard when sized for 2 filters with 2 in reserve (reducing SCFM @ 19in Hg to 346, and SCFM @ 15in Hg to 460).