Notice: A non well formed numeric value encountered in /home/powerexi/public_html/wp-content/plugins/script-insert/inc/php/versioning.php on line 41
NEW FirstCall™ Alarm Panels | POWEREX Notice: Function WP_Scripts::localize was called incorrectly. The $l10n parameter must be an array. To pass arbitrary data to scripts, use the wp_add_inline_script() function instead. Please see Debugging in WordPress for more information. (This message was added in version 5.7.0.) in /home/powerexi/public_html/wp-includes/functions.php on line 5833
Notice: Function WP_Scripts::localize was called incorrectly. The $l10n parameter must be an array. To pass arbitrary data to scripts, use the wp_add_inline_script() function instead. Please see Debugging in WordPress for more information. (This message was added in version 5.7.0.) in /home/powerexi/public_html/wp-includes/functions.php on line 5833
Notice: Function WP_Scripts::localize was called incorrectly. The $l10n parameter must be an array. To pass arbitrary data to scripts, use the wp_add_inline_script() function instead. Please see Debugging in WordPress for more information. (This message was added in version 5.7.0.) in /home/powerexi/public_html/wp-includes/functions.php on line 5833
Notice: Function WP_Scripts::localize was called incorrectly. The $l10n parameter must be an array. To pass arbitrary data to scripts, use the wp_add_inline_script() function instead. Please see Debugging in WordPress for more information. (This message was added in version 5.7.0.) in /home/powerexi/public_html/wp-includes/functions.php on line 5833
The Powerex FirstCall™ medical gas alarm systems monitor the status of medical gases in Category 1 healthcare facilities. The alarm systems are ETL listed to UL 1069 and comply with the latest edition of NFPA 99. All alarm systems provide audible and visible indications of NFPA 99 medical gas alarm conditions.
10” high-resolution touchscreen HMI with 7” VE option available
Ethernet connectivity using BACnet over IP protocol to building management system – available
Customizable emergency instructions in the event of an alarm
Area alarm up to 8 gases
Master alarm 23, 39, and 55 input signals
Combination alarm up to 6 gases, 23, 39, or 55 input signals
Designed and manufactured in the USA
5 year warranty on parts, 2 year warranty on labor
Master alarm signals organized under main source badge – click through for individual alarm information
Push-in terminal blocks to easily connect transducer and source equipment alarm signals
Factory set for normally closed signals, able to change to normally open
Transducers are gas-specific, and cross-connecting a transducer with an assigned gas input will generate an alarm per 2018 NFPA 99
Hinged frame for easy assembly and maintenance
Option for digital outputs – contact factory
Powerex FirstCall™ medical gas alarm retrofit kits are designed to upgrade or retrofit existing panels by replacing all necessary major components and reutilizing the existing back box. Powerex FirstCall™ medical gas alarm retrofit is compatible with the following alarm panels:
Amico Alert-2 (3 through 7 gang back box only)
Amico Compact Alert-2 (3 through 7 gang back box only)
Amico Alert-3
Amico Alert-4
Beacon Medaes MEGA 2
Beacon Medaes MEGA 3
Beacon Medaes TotalAlert Infinity
Ohio/Ohmeda/Medaes “Black Front”*
Hill-Rom/Beacon “Tan Front”* **
Chemetron Series 74 Impact Alarm System
Chemetron Digi I
Chemetron Digi II
Tri-Tech Medical DU/DC***
Tri-Tech Medical Med Touch***
*The Ohio/Ohmeda/Medaes Multi Module Line Pressure Alarm and the Hill-Rom/Beacon Area Line Pressure Alarm both require Hansen fittings for the transducers, so this must be indicated at the end of the part number with “-BTF.”
**The Hill-Rom/Beacon “Tan Front” 5 and 6 gas Area Alarms require a unique component layout, so this must be indicated at the end of the part number with “-TF56.”
***The Tri-Tech Medical DU/DC Series Combo and Master Alarms and Med Touch series Master Alarms greater than 24 signals require a unique component layout, so this must be indicated at the end of the part number with “-TTM”